Operating System: Refer to RAID Card for details on supported Operating Systems PERC H810
SAS connectors (per EMM): 1 SAS (SFF 8088) IN connector for connection to the host, 1 SAS (SFF 8088) OUT connector for expansion to an additional enclosure
Serial connector (per EMM): 1 6 pin UART mini-DIN connector (for factory use only)
Chassis Height : 8.7cm (3.43 inches)
Chassis Width : 48.2cm (18.98 inches)
Chassis Depth : 59.4 (23.39 inches)
Chassis Weight : 28.39 kg (62.6 lb) (maximum configuration)8.84 kg (19.5 lb) (empty)
SAS connectors (per EMM): 1 SAS (SFF 8088) IN connector for connection to the host, 1 SAS (SFF 8088) OUT connector for expansion to an additional enclosure
Serial connector (per EMM):1 6-pin UART mini-DIN connector (for factory use only)
Connectivity:
(A)Unified mode (single path) for daisy chaining of up to 8 enclosures per PERC H810 (4 enclosures per port, single path)
(B)Unified mode (redundant path) for daisy chaining up to 4 enclosures per PERC H810 (4 enclosures connected to both ports via redundant path cabling)
(C)Split mode with dual Enclosure Management Modules providing direct connectivity to drives 0 through 5 and a separate connectivity to drives 6 through 11.
Environmental Operating Conditions:
(A)Temperature:
Operating: 10° to 35°C (50° to 95°F) with maximum temp gradation of 10°C per hour
Storage: -40° to 65°C (-40° to 149°F) with temp gradation of 20°C per hour
Supports Fresh Air cooling, up to 35 degrees Celsius
(B)Relative humidity:
Operating: 8% to 85% (non-condensing) with maximum humidity gradation of 10% per hour
Storage: 5% to 95% (non-condensing)
(C)Altitude:
Operating: -16 to 3048 m (-50 to 10,000 ft)
Storage: -16 to 10,600 m (-50 to 35,000 ft)
LED Indicators :
(A)Front panel
1 two-color LED indicator for system status
2 single-color LED indicators for power and split mode
(B)Drive carrier
1 single-color activity LED
1 two-color LED status indicator per drive
(C)EMM
3 two-color LED status indicators: one each for the two EMM SAS ports and one for the EMM status
1 single-color Unit Identification LED for each EMM
(D)Power supply/cooling fan module
3 LED status indicators for power supply status, power supply/fan fault and AC status
Management :
2 Enclosure Management Modules(EMM) provide redundant enclosure management capability
Power :
Two fully redundant power supplies; supports DC power
Wattage: AC - 600 W; DC – 700 W
Heat dissipation: AC - 2047BTU/hr; DC - 2388 BTU/hr
Voltage: 100-240 VAC, auto sensing; 48V DC
Frequency: 50/60 Hz
Amperage: 8.6 A at 100 V, 4.3 A at 240 V
Available Drive Power (per slot)
Supported drive power consumption (continuous):
up to 1.16 A at +5V
up to 1.6 A +12V
RAID : PERC H800 supports RAID levels 0, 1, 5, 6, 10, 50 and 60.
Storage :
(A)Drives :
Up to twelve (12) hot-pluggable SAS Hard Disk Drives (HDDs) at 7.2K, 10K and 15K rpm and SAS Solid State Drives (SSDs)
(B)Drive performances and capacities :
(I)3.5” 6Gbps SAS:
HDD 15K – 300GB, 450GB, 600GB
HDD 7.2K – 1TB, 2TB, 3TB, 4TB
HDD 7.2K NL-SAS 512e – 6TB
(II)3.5” 12Gbps SAS:
HDD 7.2K NL-SAS 512e – 6TB, 8TB, 10TB
(III)2.5” 6Gbps SAS with 3.5” carrier:
HDD 10K – 300GB, 600GB, 900GB, 1.2TB
HDD 10K 512e– 1.8TB
SSD – 400GB mainstream SLC
SSD – 200GB, 800GB value SLC
SSD – 800GB RI MLC
SSD – 200GB, 400GB WI SLC
(IV)2.5 12Gbps SAS with 3.5 carrier: 7.2K HDD NL-SAS 512e 2TB, SSD 200GB, 400GB, 800GB, 1.6TB MU MLC
SSD – 200GB, 400GB, 800GB WI MLC
SSD – 800GB, 1.6TB RI MLC
(C)Maximum Capacity (per enclosure): Up to 120TB when using 12 x 10TB NL-SAS 3.5 HDDs
(D)Expansion Capabilities: PERC H810 Host RAID adapter enables expansion to 8 enclosures (4 enclosures per port)