  • Operating System: Refer to RAID Card for details on supported Operating Systems PERC H810
  • SAS connectors (per EMM): 1 SAS (SFF 8088) IN connector for connection to the host, 1 SAS (SFF 8088) OUT connector for expansion to an additional enclosure
  • Serial connector (per EMM): 1 6 pin UART mini-DIN connector (for factory use only)
  • Chassis Height : 8.7cm (3.43 inches) 
  • Chassis Width : 48.2cm (18.98 inches) 
  • Chassis Depth : 59.4 (23.39 inches)
  • Chassis Weight : 28.39 kg (62.6 lb) (maximum configuration)8.84 kg (19.5 lb) (empty)
  • SAS connectors (per EMM):  1 SAS (SFF 8088) IN connector for connection to the host, 1 SAS (SFF 8088) OUT connector for expansion to an additional enclosure
  • Serial connector (per EMM):1 6-pin UART mini-DIN connector (for factory use only)
  • Connectivity:
  • (A)Unified mode (single path) for daisy chaining of up to 8 enclosures per PERC H810 (4 enclosures per port, single path)
  • (B)Unified mode (redundant path) for daisy chaining up to 4 enclosures per PERC H810 (4 enclosures connected to both ports via redundant path cabling)
  • (C)Split mode with dual Enclosure Management Modules providing direct connectivity to drives 0 through 5 and a separate connectivity to drives 6 through 11.
  • Environmental Operating Conditions:
  • (A)Temperature:
  • Operating: 10° to 35°C (50° to 95°F) with maximum temp gradation of 10°C per hour
  • Storage: -40° to 65°C (-40° to 149°F) with temp gradation of 20°C per hour
  • Supports Fresh Air cooling, up to 35 degrees Celsius
  • (B)Relative humidity:
  • Operating: 8% to 85% (non-condensing) with maximum humidity gradation of 10% per hour
  • Storage: 5% to 95% (non-condensing)
  • (C)Altitude:
  • Operating: -16 to 3048 m (-50 to 10,000 ft)
  • Storage: -16 to 10,600 m (-50 to 35,000 ft)
  • LED Indicators : 
  • (A)Front panel
  • 1 two-color LED indicator for system status
  • 2 single-color LED indicators for power and split mode
  • (B)Drive carrier
  • 1 single-color activity LED
  • 1 two-color LED status indicator per drive
  • (C)EMM
  • 3 two-color LED status indicators: one each for the two EMM SAS ports and one for the EMM status
  • 1 single-color Unit Identification LED for each EMM
  • (D)Power supply/cooling fan module
  • 3 LED status indicators for power supply status, power supply/fan fault and AC status
  • Management :
  • 2 Enclosure Management Modules(EMM) provide redundant enclosure management capability
  • Power : 
  • Two fully redundant power supplies; supports DC power
  • Wattage: AC - 600 W; DC – 700 W
  • Heat dissipation: AC - 2047BTU/hr; DC - 2388 BTU/hr
  • Voltage: 100-240 VAC, auto sensing; 48V DC
  • Frequency: 50/60 Hz
  • Amperage: 8.6 A at 100 V, 4.3 A at 240 V
  • Available Drive Power (per slot)
  • Supported drive power consumption (continuous): 
  • up to 1.16 A at +5V 
  • up to 1.6 A +12V
  • RAID : PERC H800 supports RAID levels 0, 1, 5, 6, 10, 50 and 60.
  • Storage :
  • (A)Drives :
  • Up to twelve (12) hot-pluggable SAS Hard Disk Drives (HDDs) at 7.2K, 10K and 15K rpm and SAS Solid State Drives (SSDs)
  • (B)Drive performances and capacities :
  • (I)3.5” 6Gbps SAS:
  • HDD 15K – 300GB, 450GB, 600GB
  • HDD 7.2K – 1TB, 2TB, 3TB, 4TB
  • HDD 7.2K NL-SAS 512e – 6TB
  • (II)3.5” 12Gbps SAS:
  • HDD 7.2K NL-SAS 512e – 6TB, 8TB, 10TB
  • (III)2.5” 6Gbps SAS with 3.5” carrier:
  • HDD 10K – 300GB, 600GB, 900GB, 1.2TB 
  • HDD 10K 512e– 1.8TB
  • SSD – 400GB mainstream SLC
  • SSD – 200GB, 800GB value SLC 
  • SSD – 800GB RI MLC
  • SSD – 200GB, 400GB WI SLC
  • (IV)2.5 12Gbps SAS with 3.5 carrier: 7.2K HDD NL-SAS 512e 2TB, SSD 200GB, 400GB, 800GB, 1.6TB MU MLC
  • SSD – 200GB, 400GB, 800GB WI MLC
  • SSD – 800GB, 1.6TB RI MLC
  • (C)Maximum Capacity (per enclosure): Up to 120TB when using 12 x 10TB NL-SAS 3.5 HDDs 
  • (D)Expansion Capabilities: PERC H810 Host RAID adapter enables expansion to 8 enclosures (4 enclosures per port)


Detailed Specification


A PHP Error was encountered

Severity: Notice

Message: fwrite(): Write of 34 bytes failed with errno=122 Disk quota exceeded

Filename: drivers/Session_files_driver.php

Line Number: 272

Backtrace:

A PHP Error was encountered

Severity: Warning

Message: session_write_close(): Failed to write session data using user defined save handler. (session.save_path: /var/cpanel/php/sessions/ea-php81)

Filename: Unknown

Line Number: 0

Backtrace: